How to perform server hardware diagnostics in rescue mode
Find out how to use the OVHcloud rescue mode and diagnostic tools to identify hardware failures on your dedicated server
2024-05-06

Objective

At some point during the life of your server, you may encounter a fault due to a hardware issue. When the server is booted into the OVHcloud rescue mode, you have several diagnostic tools available to help identify faulty hardware components.

This guide explains how to diagnose hardware issues on your OVHcloud dedicated server.

Requirements

Instructions

This guide details the tests you need to carry out to diagnose:

  • Processors
  • Network connection
  • Memory
  • Disks and partitions

Processors

The processor test checks the working order of your server's processor, and needs about 30 minutes to run successfully. If the server crashes during this test, then it means that the processor is faulty.

WRKR=$(grep -c "^processor" /proc/cpuinfo)
stress-ng --metrics-brief --timeout 60s --cpu $WRKR --io $WRKR --aggressive --ignite-cpu --maximize --pathological
stress-ng --metrics-brief --timeout 60s --brk 0 --stack 0 --bigheap 0 

Network Connection

The network connection test checks your internal and external bandwidth. This data is provided for information purposes only and is not a performance test.

ping -c 10 proof.ovh.net
for file in 1Mb 10Mb 100Mb 1Gb ; do time curl -4f https://proof.ovh.net/files/${file}.dat -o /dev/null; done

Memory

The memory test checks the integrity of your server's RAM modules. If the server crashes during this test, then it means that the one or more of your RAM modules is faulty.

Warning

Keep in mind that this test can take a long time to complete.

RAM="$(awk -vOFMT=%.0f '$1 == "MemAvailable:" {print $2/1024 - 1024}' /proc/meminfo)"
memtester ${RAM}M 1

Disk Health

You can use Smartmontools to check the status of your disks by reading their SMART data. For example, to display all details of the disk labelled nvme1n1, enter:

smartctl -a /dev/nvme1n1

To learn more about the output of this command and how to interpret it, consult the official Smartmontools documentation.

Disk Partitions

The partitions test is comprised of a disk access test and a file system check. The disk access test checks if the system can communicate with your server's hard drives. The file system check uses the fsck -fy command to check the entire file system.

stress-ng --metrics-brief --timeout 60s --hdd 0 --aggressive

Go further