Skip to content

AS 3600 extra design point at transition in phi #21

New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Closed
robbievanleeuwen opened this issue Jul 28, 2022 Discussed in #12 · 0 comments · Fixed by #23
Closed

AS 3600 extra design point at transition in phi #21

robbievanleeuwen opened this issue Jul 28, 2022 Discussed in #12 · 0 comments · Fixed by #23
Assignees
Labels
enhancement New feature or request

Comments

@robbievanleeuwen
Copy link
Owner

Discussed in #12

Originally posted by Agent6-6-6 July 24, 2022
"where you're dealing with a variable phi, when doing the interaction curve I believe for accuracy at the point where phi changes from variable to constant you should really be injecting an additional axial load point to capture exact point of change on the interaction curve."

image

@robbievanleeuwen robbievanleeuwen added the enhancement New feature or request label Jul 28, 2022
@robbievanleeuwen robbievanleeuwen self-assigned this Jul 28, 2022
@robbievanleeuwen robbievanleeuwen linked a pull request Jul 30, 2022 that will close this issue
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Labels
enhancement New feature or request
Projects
None yet
Development

Successfully merging a pull request may close this issue.

1 participant