fix(mm): flux model variant probing #7825
Merged
Add this suggestion to a batch that can be applied as a single commit.
This suggestion is invalid because no changes were made to the code.
Suggestions cannot be applied while the pull request is closed.
Suggestions cannot be applied while viewing a subset of changes.
Only one suggestion per line can be applied in a batch.
Add this suggestion to a batch that can be applied as a single commit.
Applying suggestions on deleted lines is not supported.
You must change the existing code in this line in order to create a valid suggestion.
Outdated suggestions cannot be applied.
This suggestion has been applied or marked resolved.
Suggestions cannot be applied from pending reviews.
Suggestions cannot be applied on multi-line comments.
Suggestions cannot be applied while the pull request is queued to merge.
Suggestion cannot be applied right now. Please check back later.
Summary
In #7780 we added FLUX Fill support, and needed the probe to be able to distinguish between "normal" FLUX models and FLUX Fill models.
Logic was added to the probe to check a particular state dict key (input channels), which should be 384 for FLUX Fill and 64 for other FLUX models.
The new logic was stricter and instead of falling back on the "normal" variant, it raised when an unexpected value for input channels was detected.
This caused failures to probe for BNB-NF4 quantized FLUX Dev/Schnell, which apparently only have 1 input channel.
After checking a variety of FLUX models, I loosened the strictness of the variant probing logic to only special-case the new FLUX Fill model, and otherwise fall back to returning the "normal" variant. This better matches the old behaviour and fixes the import errors.
Related Issues / Discussions
Closes #7822
QA Instructions
Try importing quantized FLUX models. I tested and it works as it should.